ICP6810 solutions for applications in the zinc oxide industry
ICP6810 solutions for applications in the zinc oxide industry
Preface:The general classification of zinc oxide: the general industrial grade of zinc oxide is mainly divided into three kinds (pharmaceutical grade temporarily not mentioned) indirect method of zinc oxide (content 99.5-99.7),
Direct method zinc oxide (below 99), active zinc oxide!There is also a nano active zinc oxide that the number of zinc oxide order can be more than 1000 orders, but now can do very few enterprises, generally with composite active zinc oxide to replace.
Zinc oxide is used more often in the industry.The phosphorylation industry.Generally are used with higher content and purity of the indirect method of zinc oxide 99.7, phosphoride liquid for zinc oxide requirements are relatively higher to make some products to be bright.Rubber industry.Zinc oxide is used in this industry scope is relatively wide, you can say that 99.7 below can be used, the specific content is according to their own product requirements with the use of the effect to determine!Tire, sealing ring and other with 997 is more, other rubber products with what content have, now there are also a considerable number of customers to use active zinc oxide.
Ceramic fmelt industry.Now a lot of enterprises began to use high lead secondary zinc oxide to produce ceramic funk, the zinc oxide content of pigment is generally in 99.7 and zinc oxide is not easily change color, the requirements of iron content is more sensitive, specialized ceramic pigment enterprise is about 98 zinc oxide.
With the development and application of chemical products, and human production and life is closely related, so more and more stringent testing standards and requirements are put forward for the products and their raw materials,Traditional chemical analysis methods can no longer meet the requirements of daily analysis and testing.The ICP-AES inductively coupled plasma emission spectrometer is widely used in the determination of element content in the chemical industry because of its advantages of low detection limit, fast detection speed, high resolution and high accuracy.
●The ICP6810 profile is introduced
The ICP6810 full-spectrum direct-read inductance-coupled plasma emission spectrometer, with excellent resolution, test accuracy and precision, is widely used in the rare earth industry, chemical industry, andOre analysis, metal smelting, geological research, drug safety, experimental research, environmental testing, food safety and other industries.Especially for the determination of elements in the ICP6810 zinc oxide industry.
picture1.ICP6810
Table 1. Main technical parameters of ICP6810
High frequency ionizer |
|
Working frequency |
27.12MHz |
Frequency stability |
﹤0.05% |
Output power |
800W ~1600W |
Output power stability |
≤0.05% |
OMatching way |
Automatic matching |
Scan the light divider |
|
light path |
Full reflection imaging light path, quartz prism two-dimensional dispersion system |
focal distance |
400mm |
Graster specifications |
Middle step grating, 52.67, l p / mm, 64 shining angle |
Resolution ratio |
<0.0068nm@200nm |
Complete machine technical indicators |
|
Scan the wavelength range |
At 165-900nm, full wavelength coverage, and measurable Al 167.120nm |
Repetitiveness |
RSD≤1.5% |
Stability |
RSD≤2.0% |
●Samples are available for measurable element assessment
Now for the customer samples and related information, after consulting the relevant data and relevant standards, the customer samples can be accurately tested with American analysis instruments. The details are shown in Table 2:
Table 2. Sample solutions
sample |
measureelement |
Analysis instrument |
Sample handling overview (for reference only) |
remarks |
Zinc oxide material |
Copper, iron, aluminum, cadmium, manganese, arsenic, lead, etc |
ICP6810
|
Take about 0.2-0.5g of samples, add a certain amount of hydrochloric acid, and heat it at low temperature. After the solution is clear, take it off and cool it to room temperature and move it into a 100ml volumetric bottle, dilute it to the scale with water, and mix it well. |
In order to accurately determine the content of copper, iron, aluminum, cadmium and other elements. |
●location of apparatus
Table 3 shows the instrument configuration required for the determination of the sample, including the instrument host machine, accessories, sample pretreatment equipment, and reagents, etc.
Table 3.ICP6810 and related instrument configuration
Instrument host and necessary accessories |
||||||
order number |
definition |
Specifications / models |
manufacturer |
quantity remarks |
quantity remarks |
|
1 |
Full-spectrum straight-read inductively coupled plasma emission spectrometer |
ICP6810 |
Shanghai Beauty Instrument Co., Ltd |
1 |
|
|
2 |
Automatic temperature control and circulating cooling water device |
|
|
1 |
|
|
3 |
stabilized voltage supply |
|
|
1 |
|
|
Instrument matching accessories |
||||||
order number |
definition |
Specifications / models |
manufacturer |
quantity remarks |
quantity remarks |
|
1 |
host |
|
|
1 |
|
|
2 |
graphoscope |
|
|
1 |
|
|
3 |
marking punch |
|
|
1 |
|
|
Sample processing equipment and consumables |
||||||
order number |
definition |
Specifications / models |
manufacturer |
quantity remarks |
quantity remarks |
|
1 |
Electronictemperature-controlled heating board |
EG-35B |
|
1 |
|
|
2 |
One in ten thousand is an electronic balance |
BS224S |
|
1 |
|
|
3 |
Laboratory-grade ultra-pure water machine |
EPED-40T |
|
1 |
|
|
4 |
Disposable rubber Gloves |
M |
|
/ |
|
|
5 |
Activated carbon mask |
|
|
/ |
|
|
6 |
3mlpasteurpipette |
3ml |
|
/ |
|
|
7 |
100mlglass beaker |
100ml |
Sichuan Shu Glass scientific Instruments |
/ |
|
|
8 |
100mlGlass capacity bottle |
100ml |
Sichuan Shu Glass scientific Instruments |
/ |
|
|
9 |
5mltransfer liquid gun |
0.5ml-5ml |
Rand, Germany |
1 |
|
|
10 |
1mltransfer liquid gun |
100ul-1000ul |
Rand, Germany |
1 |
|
|
Reagent |
||||||
order number |
definition |
Specifications / models |
manufacturer |
quantity remarks |
quantity remarks |
|
1 |
hydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltd |
hydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltd |
hydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltd |
/ |
|
|
2 |
hydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltd |
hydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltd |
hydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltd |
/ |
|
|
3 |
perhydrol GR Jiangsu Qiangsheng Chemical Co., Ltd |
perhydrol GR Jiangsu Qiangsheng Chemical Co., Ltd |
perhydrol GR Jiangsu Qiangsheng Chemical Co., Ltd |
/ |
|
|
4 |
Standard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysis |
Standard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysis |
Standard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysis |
/ |
|
If you have any other questions, please call the analysis instrument