2024最新国产不卡a视频_欧美日韩一级片在线观看_国产任我在线精品_成人自拍视频在线_亚洲欧美日韩AⅤ在线观看_中文国产成人精品视频久_亚洲图片另类久久_麻豆国产美女遭强高潮免费视频_精品999无码在线观看_中文字幕有码自拍欧美

Inductively coupled plasma emission

ICP6810 solutions for applications in the zinc oxide industry

Time:2022-06-20  Read:

ICP6810 solutions for applications in the zinc oxide industry

Preface:The general classification of zinc oxide: the general industrial grade of zinc oxide is mainly divided into three kinds (pharmaceutical grade temporarily not mentioned) indirect method of zinc oxide (content 99.5-99.7),

Direct method zinc oxide (below 99), active zinc oxide!There is also a nano active zinc oxide that the number of zinc oxide order can be more than 1000 orders, but now can do very few enterprises, generally with composite active zinc oxide to replace.
     Zinc oxide is used more often in the industry.The phosphorylation industry.Generally are used with higher content and purity of the indirect method of zinc oxide 99.7, phosphoride liquid for zinc oxide requirements are relatively higher to make some products to be bright.Rubber industry.Zinc oxide is used in this industry scope is relatively wide, you can say that 99.7 below can be used, the specific content is according to their own product requirements with the use of the effect to determine!Tire, sealing ring and other with 997 is more, other rubber products with what content have, now there are also a considerable number of customers to use active zinc oxide.

     Ceramic fmelt industry.Now a lot of enterprises began to use high lead secondary zinc oxide to produce ceramic funk, the zinc oxide content of pigment is generally in 99.7 and zinc oxide is not easily change color, the requirements of iron content is more sensitive, specialized ceramic pigment enterprise is about 98 zinc oxide.

With the development and application of chemical products, and human production and life is closely related, so more and more stringent testing standards and requirements are put forward for the products and their raw materials,Traditional chemical analysis methods can no longer meet the requirements of daily analysis and testing.The ICP-AES inductively coupled plasma emission spectrometer is widely used in the determination of element content in the chemical industry because of its advantages of low detection limit, fast detection speed, high resolution and high accuracy.

The ICP6810 profile is introduced

The ICP6810 full-spectrum direct-read inductance-coupled plasma emission spectrometer, with excellent resolution, test accuracy and precision, is widely used in the rare earth industry, chemical industry, andOre analysis, metal smelting, geological research, drug safety, experimental research, environmental testing, food safety and other industries.Especially for the determination of elements in the ICP6810 zinc oxide industry.

picture1.ICP6810

 


Table 1. Main technical parameters of ICP6810

High frequency ionizer

Working frequency

27.12MHz

Frequency stability

0.05%

Output power

 800W ~1600W

Output power stability

 ≤0.05%

OMatching way

Automatic matching

Scan the light divider

light path

Full reflection imaging light path, quartz prism two-dimensional dispersion system

focal distance

400mm

Graster specifications

Middle step grating, 52.67, l p / mm, 64 shining angle

Resolution ratio

<0.0068nm@200nm

Complete machine technical indicators

Scan the wavelength range

At 165-900nm, full wavelength coverage, and measurable Al 167.120nm

Repetitiveness

RSD≤1.5%

Stability

RSD≤2.0%

●Samples are available for measurable element assessment

Now for the customer samples and related information, after consulting the relevant data and relevant standards, the customer samples can be accurately tested with American analysis instruments. The details are shown in Table 2:

Table 2. Sample solutions

sample

measureelement

Analysis instrument

Sample handling overview (for reference only)

remarks

Zinc oxide material

Copper, iron, aluminum, cadmium, manganese, arsenic, lead, etc

ICP6810

 

Take about 0.2-0.5g of samples, add a certain amount of hydrochloric acid, and heat it at low temperature. After the solution is clear, take it off and cool it to room temperature and move it into a 100ml volumetric bottle, dilute it to the scale with water, and mix it well.

In order to accurately determine the content of copper, iron, aluminum, cadmium and other elements.

location of apparatus

Table 3 shows the instrument configuration required for the determination of the sample, including the instrument host machine, accessories, sample pretreatment equipment, and reagents, etc.

Table 3.ICP6810 and related instrument configuration


Instrument host and necessary accessories

order number

definition

Specifications / models

manufacturer

quantity remarks

quantity remarks

1

Full-spectrum straight-read inductively coupled plasma emission spectrometer

ICP6810

Shanghai Beauty Instrument Co., Ltd

1

 

2

Automatic temperature control and circulating cooling water device

 

 

1

 

3

stabilized voltage supply

 

 

1

 

Instrument matching accessories

order number

definition

Specifications / models

manufacturer

quantity remarks

quantity remarks

1

host

 

 

1

 

2

graphoscope

 

 

1

 

3

marking punch

 

 

1

 

Sample processing equipment and consumables

order number

definition

Specifications / models

manufacturer

quantity remarks

quantity remarks

1

Electronictemperature-controlled heating board

EG-35B

 

1

 

2

One in ten thousand is an electronic balance

BS224S

 

1

 

3

 Laboratory-grade ultra-pure water machine

EPED-40T

 

1

 

4

Disposable rubber Gloves

M

 

/

 

5

Activated carbon mask

 

 

/

 

6

3mlpasteurpipette

3ml

 

/

 

7

100mlglass beaker

100ml

Sichuan Shu Glass scientific Instruments

/

 

8

100mlGlass capacity bottle

100ml

Sichuan Shu Glass scientific Instruments

/

 

9

5mltransfer liquid gun

0.5ml-5ml

Rand, Germany

1

 

10

1mltransfer liquid gun

100ul-1000ul

Rand, Germany

1

 

Reagent

order number

definition

Specifications / models

manufacturer

quantity remarks

quantity remarks

1

hydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltd

hydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltd

hydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltd

/

 

2

hydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltd

hydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltd

hydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltd

/

 

3

perhydrol GR Jiangsu Qiangsheng Chemical Co., Ltd

perhydrol GR Jiangsu Qiangsheng Chemical Co., Ltd

perhydrol GR Jiangsu Qiangsheng Chemical Co., Ltd

/

 

4

Standard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysis

Standard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysis

Standard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysis

/

 


If you have any other questions, please call the analysis instrument